Over-the-side heaters are ideal for heating water, oils, solvents, salts and acids. Over-the-side heater application versatility is enhanced with optional sheath materials, kilowatt ratings, terminal enclosures and mounting methods.
The L and O shaped “installed-from-the-top” heaters slide easily into tanks, with the heated portion immersed along the side or at the bottom. The drum immersion heaters are designed for direct immersion in a standard 55 gallon steel drum. Watlow® vertical loop immersion heaters are well-suited for open tank applications.
Material | Maximum Operating Temperatures | Maximum Watt Densities | ||
---|---|---|---|---|
°F | °C | W/in2 | W/cm2 | |
Alloy 800 | 1600 | 870 | 60 | 9.3 |
N/A | 1400 | 760 | 43 | 6.7 |
N/A | 750 | 400 | 23 | 3.6 |
N/A | 1200 | 650 | 60 | 9.3 |
Features | Benefits |
---|---|
Rugged, light-weight construction |
|
0.475 in. (12 mm) diameter WATROD heating elements |
|
WATROD hairpins are repressed (recompacted) |
|
Four inch (100 mm) sludge legs |
|
RTV riser seal |
|
Standardized size 1 in. (25 mm) conduit openings |
|
SRG insulated flexible lead wires, rated to 390°F (200°C) |
|
Riser materials are compatible with element sheath materials such as stainless steel with Incoloy® sheath and steel with steel sheath |
|
HTUK Services Ltd:
Alexandra Building,
Wearfield, Sunderland,
SR5 2TA
Phone : 0044 (0191) 5166636
Fax : (0191) 5166686
Email : enquiries@ht-uk.com /
sales@ht-uk.com
www.htuk-services.co.uk